2.
BMC Med ; 22(1): 130, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38519982

RESUMO

BACKGROUND: Comprehensive data on patients at high risk of sudden cardiac death (SCD) in emerging countries are lacking. The aim was to deepen our understanding of the SCD phenotype and identify risk factors for death among patients at high risk of SCD in emerging countries. METHODS: Patients who met the class I indication for implantable cardioverter-defibrillator (ICD) implantation according to guideline recommendations in 17 countries and regions underrepresented in previous trials were enrolled. Countries were stratified by the WHO regional classification. Patients were or were not implanted with an ICD at their discretion. The outcomes were all-cause mortality and SCD. RESULTS: We enrolled 4222 patients, and 3889 patients were included in the analysis. The mean follow-up period was 21.6 ± 10.2 months. There were 433 (11.1%) instances of all-cause mortality and 117 (3.0%) cases of SCD. All-cause mortality was highest in primary prevention (PP) patients from Southeast Asia and secondary prevention (SP) patients from the Middle East and Africa. The SCD rates among PP and SP patients were both highest in South Asia. Multivariate Cox regression modelling demonstrated that in addition to the independent predictors identified in previous studies, both geographic region and ICD use were associated with all-cause mortality in patients with high SCD risk. Primary prophylactic ICD implantation was associated with a 36% (HR = 0.64, 95% CI 0.531-0.802, p < 0.0001) lower all-cause mortality risk and an 80% (HR = 0.20, 95% CI = 0.116-0.343, p < 0.0001) lower SCD risk. CONCLUSIONS: There was significant heterogeneity among patients with high SCD risk in emerging countries. The influences of geographic regions on patient characteristics and outcomes were significant. Improvement in increasing ICD utilization and uptake of guideline-directed medical therapy in emerging countries is urgent. TRIAL REGISTRATION: ClinicalTrials.gov, NCT02099721.


Assuntos
Desfibriladores Implantáveis , Humanos , Fatores de Risco , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , África , Oriente Médio
3.
Eur Heart J Suppl ; 25(Suppl H): H22-H26, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38046889

RESUMO

As the aging population continues to grow, so has the incidence of cardiovascular diseases, including bradycardia, with much of the burden falling on low- and middle-income countries (LMICs). Pacemaker therapy remains the only guideline-recommended therapy for symptomatic bradycardia, but due to the cost and expertise required for pacemaker implants, patients in LMICs have less access to pacemaker therapies. However, with the concerted effort of organizations (governments, non-governmental organizations, industry, and medical societies) strides can continue to be made in improving access to care. Governments play a role in extending health coverage to its citizens and improving their physical and digital healthcare infrastructure. Non-governmental organizations promote access and awareness through charity and advocacy programs. Industries can continue innovating technology that is both affordable and accessible. Medical societies provide guidelines for treatment and necessary educational and networking opportunities for physicians who serve in LMICs. All of these organizations have individual responsibilities and goals in expanding access to bradycardia therapy, which can be more easily realized by their continued collaboration.

4.
Heart Rhythm O2 ; 4(11): 741-755, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38034890

RESUMO

On May 27, 2022, the Asia Pacific Heart Rhythm Society and the Heart Rhythm Society convened a meeting of leaders from different professional societies of healthcare providers committed to arrhythmia care from the Asia Pacific region. The overriding goals of the meeting were to discuss clinical and health policy issues that face each country for providing care for patients with electrophysiologic issues, share experiences and best practices, and discuss potential future solutions. Participants were asked to address a series of questions in preparation for the meeting. The format of the meeting was a series of individual country reports presented by the leaders from each of the professional societies followed by open discussion. The recorded presentations from the Asia Summit can be accessed at https://www.heartrhythm365.org/URL/asiasummit-22. Three major themes arose from the discussion. First, the major clinical problems faced by different countries vary. Although atrial fibrillation is common throughout the region, the most important issues also include more general issues such as hypertension, rheumatic heart disease, tobacco abuse, and management of potentially life-threatening problems such as sudden cardiac arrest or profound bradycardia. Second, there is significant variability in the access to advanced arrhythmia care throughout the region due to differences in workforce availability, resources, drug availability, and national health policies. Third, collaboration in the area already occurs between individual countries, but no systematic regional method for working together is present.

5.
J Electrocardiol ; 81: 230-236, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37844372

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a cause of serious morbidity such as stroke. Early detection and treatment of AF is important. Current guidelines recommend screening via opportunistic pulse taking or 12­lead electrocardiogram. Mid-term ECG patch monitors increases the sensitivity of AF detection. METHODS: The Singapore Atrial Fibrillation Study is a prospective multi-centre study aiming to study the incidence of AF in patients with no prior AF and a CHA2DS2-VASc score of at least 1, with the use of a mid-term continuous ECG monitoring device (Spyder ECG). Consecutive patients from both inpatient and outpatient settings were recruited from 3 major hospitals from May 2016 to December 2019. RESULTS: Three hundred and fifty-five patients were monitored. 6 patients (1.7%) were diagnosed with AF. There were no significant differences in total duration of monitoring between the AF and non-AF group (6.39 ± 3.19 vs 5.42 ± 2.46 days, p = 0.340). Patients with newly detected AF were more likely to have palpitations (50.0% vs 11.8%, p = 0.027). Half of the patients (n = 3, 50.0%) were diagnosed on the first day of monitoring and the rest were diagnosed after 24 h. On univariate analysis, only hyperlipidemia was associated with reduced odds of being diagnosed with AF (OR HR 0.08 CI 0.01-0.74, p = 0.025). In a group of 128 patients who underwent coronary artery bypass grafting and had post-operative ECG monitoring, 9 patients (7.0%) were diagnosed with post-operative AF. CONCLUSIONS: The use of non-invasive mid-term patch-based ECG monitoring is an effective modality for AF screening.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Eletrocardiografia , Estudos Prospectivos , Programas de Rastreamento
7.
Indian Heart J ; 75(2): 115-121, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36736459

RESUMO

BACKGROUND & OBJECTIVE: Despite the burden of sudden cardiac arrest (SCA) worldwide, implantable cardioverter-defibrillators (ICDs) are underutilized, particularly in Asia, Latin America, Eastern Europe, the Middle East, and Africa. The Improve SCA trial demonstrated that primary prevention (PP) patients in these regions benefit from an ICD or a cardiac resynchronization therapy defibrillator (CRT-D). We aimed to compare the rate of device therapy and mortality among ischemic and non-ischemic cardiomyopathy (ICM and NICM) PP patients who met guideline indications for ICD therapy and had an ICD/CRT-D implanted. METHODS: Improve SCA was a prospective, non-randomized, non-blinded multicenter trial that enrolled patients from the above-mentioned regions. All-cause mortality and device therapy were examined by cardiomyopathy (ICM vs NICM) and implantation status. Cox proportional hazards methods were used, adjusting for factors affecting mortality risk. RESULTS: Of 1848 PP NICM patients, 1007 (54.5%) received ICD/CRT-D, while 303 of 581 (52.1%) PP ICM patients received an ICD/CRT-D. The all-cause mortality rate at 3 years for NICM patients with and without an ICD/CRT-D was 13.1% and 18.3%, respectively (HR 0.51, 95% CI 0.38-0.68, p < 0.001). Similarly, all-cause mortality at 3 years in ICM patients was 13.8% in those with a device and 19.9% in those without an ICD/CRT-D (HR 0.54, 95% CI 0.33-.0.88, p = 0.011). The time to first device therapy, time to first shock, and time to first antitachycardia pacing (ATP) therapy were not significantly different between groups (p ≥ 0.263). CONCLUSIONS: In this large data set of patients with a guideline-based PP ICD indication, defibrillator device implantation conferred a significant mortality benefit in both NICM and ICM patients. The rate of appropriate device therapy was also similar in both groups. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov ID: NCT02099721.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatias , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Estudos Prospectivos , Resultado do Tratamento , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Terapia de Ressincronização Cardíaca/métodos , Fatores de Risco , Insuficiência Cardíaca/terapia
8.
J Arrhythm ; 38(5): 827-830, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36226093

RESUMO

Palpitations is one of the most common side effects experienced post-messenger-RNA COVID-19 vaccines. However, some patients experience significant symptoms and further workup needs to be considered. We present an interesting case of inappropriate sinus tachycardia in a fit gentleman who presented with worsening palpitations and elevated heart rate post-first and -second dose of the Pfizer/BioNTech vaccine.

9.
Front Cardiovasc Med ; 9: 968630, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36072865

RESUMO

Left atrial appendage (LAA) is believed to be a common site of thrombus formation in patients with atrial fibrillation (AF). However, the commonly-applied stroke risk stratification model (such as. CHA2DS2-VASc score) does not include any structural or hemodynamic features of LAA. Recent studies have suggested that it is important to incorporate LAA geometrical and hemodynamic features to evaluate the risk of thrombus formation in LAA, which may better delineate the AF patients for anticoagulant administration and prevent strokes. This review focuses on the LAA-related factors that may be associated with thrombus formation and cardioembolic events.

10.
J Arrhythm ; 38(3): 416-424, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35785374

RESUMO

Background: Sudden cardiac arrest with or without sudden cardiac death (SCD) represents a heterogeneous spectrum of underlying etiology but is often a catastrophic event. Despite improvements in pre-hospital response and post-resuscitation care, outcomes remain grim. Thus, we aim to evaluate the predictors of survival in out-of-hospital cardiac arrests (OHCAs) and describe autopsy findings of those with the uncertain cause of death (COD). Methods: This is a subgroup analysis of the Singapore cohort from the Pan Asian Resuscitation Outcome Study which studied 933 OHCAs admitted to two Singapore tertiary hospitals from April 2010 to May 2012. Results: Of the patients analysed, 30.2% (n = 282) had an initial return of spontaneous circulation (ROSC) at the emergency department, 18.0% (n = 168) had sustained ROSC with subsequent admission and 3.4% (n = 32) had survival to discharge. On multivariate analysis, an initial shockable rhythm, a witnessed event, prehospital defibrillation, and shorter time to hospital predicted ROSC as well as survival to discharge. A total of 163 (17.5%) autopsies were performed of which a cardiac etiology of SCD was noted in 92.1% (n = 151). Ischemic heart disease accounted for 54.3% (n = 89) of the autopsy cohort, with acute myocardial infarction (26.9%, n = 44) and myocarditis (3.7%, n = 6) rounding out the top three causes of demise. Conclusion: OHCA remains a clinical presentation that portends a poor prognosis. Of those with uncertain COD, cardiac etiology appears to predominate from autopsy study. Identification of prognostic factors will play an important role in improving individual-level and systemic-level variables to further optimize outcomes.

11.
Pacing Clin Electrophysiol ; 45(5): 666-673, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35417608

RESUMO

AIMS: Conduction system pacing has gained steady interest over recent years. While the majority of tools and delivery techniques were developed for His bundle pacing (HBP), the feasibility and reproducibility of using these similar tools for left bundle branch pacing (LBBP) has yet to be determined. We describe our technique for performing LBBP using the Abbott Agilis HisPro™ Steerable Catheter. METHODS AND RESULTS: A series of 22 patients with a mean age of 71.7 years (16 males, 72.7%), underwent LBBP procedure with this catheter between May and October 2021. Nineteen patients (86%) had successful LBBP lead implantation. There were no major complications or mortality. CONCLUSION: The Agilis HisPro™ catheter along with the stylet driven Tendril STS Model 2088TC lead is a safe and feasible delivery system for LBBP.


Assuntos
Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca , Idoso , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Cateteres , Eletrocardiografia , Sistema de Condução Cardíaco , Humanos , Masculino , Reprodutibilidade dos Testes
12.
Pacing Clin Electrophysiol ; 45(1): 50-58, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34792208

RESUMO

BACKGROUND: The Singapore Cardiac Databank was designed to monitor the performance and outcomes of catheter ablation. We investigated the outcomes of paroxysmal supraventricular tachycardia (PSVT)-ablation in a prospective, nationwide, cohort study. METHODS: Atrioventricular nodal re-entrant tachycardia (AVNRT), atrioventricular re-entry tachycardia (AVRT), or atrial tachycardia (AT)-ablations in Singapore from 2010 to 2018 were studied. Outcomes include acute success, periprocedural-complications, postoperative pacing requirement, arrhythmic recurrence and 1-year all-cause mortality. RESULTS: Among 2260 patients (mean age 45 ± 18 years, 50% female, 57% AVNRT, 37% AVRT, 6% AT), overall acute success rates of PSVT-ablation was 98.4% and increased in order of AT, AVRT, and AVNRT (p < .001). Periprocedural cardiac tamponade occurred in two AVRT patients. A total of 15 pacemakers (6 within first 30-days, 9 after 30-days) were implanted (seven AV block, eight sinus node dysfunction [SND]), with the highest incidence of pacemaker implantation after AT-ablation (5% vs. 0.6% AVNRT vs. 0.1% AVRT, p < .001). Repeat ablations (0.9% AVNRT, 7% AVRT, 4% AT, p < .001) were performed in 78 (3.5%) patients and 13 (0.6%) patients died within a year of ablation. Among outcomes considered adjusting for age, sex, PSVT-type and procedure-time, AT was independently associated with 6-fold increased odds of total (adjusted odds ratio [AOR] 6.32, 95% confidence interval [CI] 1.95-20.53) and late (AOR 6.38, 95% CI 1.39-29.29) pacemaker implantation, while AVRT was associated with higher arrhythmic recurrence with repeat ablations (AOR 4.72, 95% CI 2.36-9.44) compared to AVNRT. CONCLUSIONS: Contemporary PSVT ablation is safe with high acute success rates. Long-term outcomes differed by nature of the PSVT.


Assuntos
Ablação por Cateter/métodos , Taquicardia Supraventricular/cirurgia , Estimulação Cardíaca Artificial/estatística & dados numéricos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Recidiva , Sistema de Registros , Singapura/epidemiologia , Taquicardia Supraventricular/epidemiologia , Taquicardia Supraventricular/mortalidade
13.
J Cardiovasc Electrophysiol ; 32(8): 2285-2294, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34216069

RESUMO

BACKGROUND: In primary prevention (PP) patients the utilization of implantable cardioverter-defibrillators (ICD) and cardiac resynchronization therapy-defibrillators (CRT-D) remains low in many geographies, despite the proven mortality benefit. PURPOSE: The objective of this analysis was to examine the mortality benefit in PP patients by guideline-indicated device type: ICD and CRT-D. METHODS: Improve sudden cardiac arrest was a prospective, nonrandomized, nonblinded multicenter trial that enrolled patients from regions where ICD utilization is low. PP patient's CRT-D or ICD eligibility was based upon the 2008 ACC/AHA/HRS and 2006 ESC guidelines. Mortality was assessed according to guideline-indicated device type comparing implanted and nonimplanted patients. Cox proportional hazards methods were used, adjusting for known factors affecting mortality risk. RESULTS: Among 2618 PP patients followed for a mean of 20.8 ± 10.8 months, 1073 were indicated for a CRT-D, and 1545 were indicated for an ICD. PP CRT-D-indicated patients who received CRT-D therapy had a 58% risk reduction in mortality compared with those without implant (adjusted hazard ratio [HR]: 0.42, 95% confidence interval [CI]: 0.28-0.61, p < .0001). PP patients with an ICD indication had a 43% risk reduction in mortality with an ICD implant compared with no implant (adjusted HR: 0.57, 95% CI: 0.41-0.81, p = .002). CONCLUSIONS: This analysis confirms the mortality benefit of adherence to guideline-indicated implantable defibrillation therapy for PP patients in geographies where ICD therapy was underutilized. These results affirm that medical practice should follow clinical guidelines when choosing therapy for PP patients who meet the respective defibrillator device implant indication.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Prevenção Primária , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
14.
Glob Heart ; 16(1): 41, 2021 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-34211827

RESUMO

The World Heart Federation (WHF) commenced a Roadmap initiative in 2015 to reduce the global burden of cardiovascular disease and resultant burgeoning of healthcare costs. Roadmaps provide a blueprint for implementation of priority solutions for the principal cardiovascular diseases leading to death and disability. Atrial fibrillation (AF) is one of these conditions and is an increasing problem due to ageing of the world's population and an increase in cardiovascular risk factors that predispose to AF. The goal of the AF roadmap was to provide guidance on priority interventions that are feasible in multiple countries, and to identify roadblocks and potential strategies to overcome them. Since publication of the AF Roadmap in 2017, there have been many technological advances including devices and artificial intelligence for identification and prediction of unknown AF, better methods to achieve rhythm control, and widespread uptake of smartphones and apps that could facilitate new approaches to healthcare delivery and increasing community AF awareness. In addition, the World Health Organisation added the non-vitamin K antagonist oral anticoagulants (NOACs) to the Essential Medicines List, making it possible to increase advocacy for their widespread adoption as therapy to prevent stroke. These advances motivated the WHF to commission a 2020 AF Roadmap update. Three years after the original Roadmap publication, the identified barriers and solutions were judged still relevant, and progress has been slow. This 2020 Roadmap update reviews the significant changes since 2017 and identifies priority areas for achieving the goals of reducing death and disability related to AF, particularly targeted at low-middle income countries. These include advocacy to increase appreciation of the scope of the problem; plugging gaps in guideline management and prevention through physician education, increasing patient health literacy, and novel ways to increase access to integrated healthcare including mHealth and digital transformations; and greater emphasis on achieving practical solutions to national and regional entrenched barriers. Despite the advances reviewed in this update, the task will not be easy, but the health rewards of implementing solutions that are both innovative and practical will be great.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Administração Oral , Anticoagulantes/uso terapêutico , Inteligência Artificial , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Humanos
17.
Singapore Med J ; 62(8): 390-403, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-35001112

RESUMO

Advanced cardiac life support (ACLS) emphasises the use of advanced airway management and ventilation, circulatory support and the appropriate use of drugs in resuscitation, as well as the identification of reversible causes of cardiac arrest. Extracorporeal cardiopulmonary resuscitation and organ donation, as well as special circumstances including drowning, pulmonary embolism and pregnancy are addressed. Resuscitation does not end with ACLS but must continue in post-resuscitation care. ACLS also covers the recognition and management of unstable pre-arrest tachy- and bradydysrhythmias that may deteriorate further.


Assuntos
Suporte Vital Cardíaco Avançado , Reanimação Cardiopulmonar , Parada Cardíaca , Suporte Vital Cardíaco Avançado/métodos , Manuseio das Vias Aéreas , Parada Cardíaca/terapia , Humanos , Guias de Prática Clínica como Assunto , Singapura
SELEÇÃO DE REFERÊNCIAS